TEMPERATURE CONTROLLERS TH-M6 series
|
|
Thermoplay presents the new temperature controller TH-M6 which is provided with important technological improvements in relation to the other models present in the market. This temperature controller is available in 6 and 12 zones and its distribution price is very competitive.
Key features:
- Synchronous heating of all the zones despite the different thermal inertia: the delay in the heating start of the nozzles is no more required.
- Autoslave in case of TC failure: each zone can be linked to another with similar thermal behaviour. This is a more accurate alternative to the open loop mode (manual mode)
- Plastic leakage alarm: with a continuous monitoring of the power consumption, the leakage from a nozzle is detected and major damage due to the plastic leakage can be avoided
- Collective modification: temperature setting and all the control and alarms parameters can be modified at once onall the zones by pressing a button on the frontal panel
- Immediate and complete diagnostic: 6 led per zone indicate all the possible failures in the heating loop. In detail the controller recognizes and displays: thermocouple errors (breaking and inverted connection), fuse, heater and solid state relay faults, phase voltage missing
- 16 A max. per zone (3500 W) also contemporary, thanks to the high performance, self ventilated heat sink
- Heaters drying with single phase modulation
- Output powers are not synchronous in order to avoid peaks in power supply line
- 2 independent set points
In addition the TH-M6 controller has the following optional functions:
- Interconnection of two temperature controllers: the connected zones will follow the same incremental temperature ramp
- Remote connection between serial port RS-485
- Digital inputs - outputs for alarms and enabling control towards the press and others auxiliary devices
|
|
|
Technical characteristics:
-
Supply voltage 400V 3 phases with neutral, 240V 3 phases without neutral
- Main protection with a miniature circuit breaker, 32A/phase (6 zones) or 50A/phase (12 zones)
- Auto tuning of the PID algorithm parameters
- High insulation thermocouple input circuits
- Max working temperature: 50°C
- TC input: J or K, insulated or grounded
- Connection cable control unit-mold shielded
- Wide graphic display (260x64 pixel): all the information related to each zone are displayed contemporary
- Scrolling messages help the operator in case of alarm
- Multi language (italian, english, french, german)
- CE certification
- Dimensions: 340 L x 160 H x 420 P mm (6 zones)
390 L x 210 H x 480 P mm (12 zones)
|