Manifolds with 1 drop are not to be considered as standard, as the distance between axes are not fixed but they can vary as indicated in the catalogue.
For this reason, no code is indicated in the catalogue, and the client must specify the distance between axes in the order.
The dimensions indicated in the related drawings are standard, with the wire exit on the side of injection bushing. For requirements different from those indicated in these pages, the client must order a special product.
Nevertheless, the client can construct the seat of the manifold by using dimensions indicated in the catalogue.
In the design the client can calculate the power zones for the temperature controllers on the basis of the Watts indicated.
Differently from the other standard manifolds, 1 drop manifolds are also available in two versions, with pneumatic or pneumatic-hydraulic shut off groups.
|